University of Mosul
  • Register
  • Login
  • العربیة

Journal of Education and Science

Notice

As part of Open Journals’ initiatives, we create website for scholarly open access journals. If you are responsible for this journal and would like to know more about how to use the editorial system, please visit our website at https://ejournalplus.com or
send us an email to info@ejournalplus.com

We will contact you soon

  1. Home
  2. Articles in Press
  3. Authors

Current Issue

By Issue

By Subject

Keyword Index

Author Index

Indexing Databases XML

About Journal

Aims and Scope

Editorial Board

Editorial Staff

Facts and Figures

Publication Ethics

Indexing and Abstracting

Peer Review Process

News

Determined the bulk etch rate VB by different methods for nuclear track detector CR-39

    Zainab H Mohialdeen Mushtaq Abed Al-Jubbori

Journal of Education and Science, In Press
10.33899/edusj.2023.137160.1297

  • Show Article
  • Download
  • Cite
  • Statistics
  • Share

Abstract

In this study, the bulk etch rate (VB) was measured by three different methods forCR-39 with a thickness of 200µm and an area of (1 × 1 cm2), where CR_39 was irradiated through from Am241source with energy of alpha particles is 2.6MeV and at an angle of fall perpendicular to the surface of the CR-39 detector, the detector etching with (NaOH) at a concentration of 6.25N and (70 ± 1°C) and showing the effects formed on the surface of the detector with time periods ranging from (0.25h) and the formed effects were photographed In the detector at different eching times using an optical microscope of the type (XSZ-H Series Biological Microscope) equipped with a digital camera of the type (MADC_5A) connected to a personal computer, in order to find the length, thickness and diameters of the track formed on the surface of the detector.VB determind by methods are: Removed thickness method, the second method, the saturation track method, and the diameter-length method (D_L method), as the first method does not require irradiation of the detector, but the other two methods require irradiation of the detector and measurement of lengths and diameters And the time of proving the effect, and we found that the values of VB rate for the three methods, the removed thickness method, the saturation track method, and the diameter-length of the effect ((D_L method) respectively are:, (1.206, 1.204, 1.271 (µm/h) and compare the results between the mentioned methods, as we found that they are close.
Keywords:
    Alpha particles CR_39 detector Bulk etch rate Track depth Removed layer
Main Subjects:
  • Nuclear physics
  • PDF
  • XML
(2023). Determined the bulk etch rate VB by different methods for nuclear track detector CR-39. Journal of Education and Science, (), -. doi: 10.33899/edusj.2023.137160.1297
Zainab H Mohialdeen; Mushtaq Abed Al-Jubbori. "Determined the bulk etch rate VB by different methods for nuclear track detector CR-39". Journal of Education and Science, , , 2023, -. doi: 10.33899/edusj.2023.137160.1297
(2023). 'Determined the bulk etch rate VB by different methods for nuclear track detector CR-39', Journal of Education and Science, (), pp. -. doi: 10.33899/edusj.2023.137160.1297
Determined the bulk etch rate VB by different methods for nuclear track detector CR-39. Journal of Education and Science, 2023; (): -. doi: 10.33899/edusj.2023.137160.1297
  • RIS
  • EndNote
  • BibTeX
  • APA
  • MLA
  • Harvard
  • Vancouver
  • Article View: 35
  • PDF Download: 0
  • LinkedIn
  • Twitter
  • Facebook
  • Google
  • Telegram
  • Home
  • Glossary
  • News
  • Aims and Scope
  • Privacy Policy
  • Sitemap

Journal of Education and Science is licensed under a Creative Commons Attribution 4.0 International (CC-BY 4.0)

Powered by eJournalPlus